AOU
2. 更换失效件的同时务必控制好全部的相关参数;
以博世CRIN2/3为例,更换不同的部件组件,需要控制不同的参数,如下所述:
柱塞 | A | 131154-0520 | A247 |
柱塞 | A | 131152-9320 | A235 |
柱塞 | A | 131152-9120 | A233 |
柱塞 | A | 131152-8720 | A229 |
柱塞 | A | 131152-8520 | A226 |
柱塞 | A | 131152-8320 | A223 |
柱塞 | A | 131152-8020 | A220 |
柱塞 | A | 131152-7520 | A214 |
柱塞 | A | A213 | A213 |
柱塞 | A | 131152-7320 | A210 |
柱塞 | A | 131152-6920 | A205 |
柱塞 | A | 131152-6820 | A204 |
柱塞 | A | 131152-5620 | A188 |
柱塞 | A | 131152-5520 | A186 |
柱塞 | A | 131152-5320 | A183 |
柱塞 | A | 131152-5220 | A182 |
柱塞 | A | 131152-4820 | A177 |
柱塞 | A | 131152-4520 | A174 |
柱塞 | A | A173 | A173 |
柱塞 | A | 131152-4320 | A172 |
柱塞 | A | 131151-0120 | A17 |
柱塞 | A | 131152-4020 | A168 |
柱塞 | A | 131152-3520 | A162 |
柱塞 | A | 131152-3420 | A161 |
柱塞 | A | 131152-3320 | A160 |
柱塞 | A | 131152-3120 | A158 |
柱塞 | A | 131152-3020 | A157 |
柱塞 | A | 131151-2820 | A154 |
柱塞 | A | 131102-0020 | A15 |
柱塞 | A | 131152-2320 | A149 |
柱塞 | A | 131152-2220 | A148 |
柱塞 | A | 131153-0520 | A147 |
柱塞 | A | 131152-2120 | A146 |
柱塞 | A | 131152-1420 | A138 |
柱塞 | A | 131152-1220 | A136 |
柱塞 | A | 131152-8220 | A126 |
柱塞 | A | 131152-0320 | A125 |
柱塞 | A | 131152-0020 | A122 |
柱塞 | A | 131152-0120 | A120 |
柱塞 | A | 131151-9820 | A117 |
柱塞 | A | 95.16U | 95.16U |
1)更换衔铁组件:衔铁升程、缓冲升程、电磁阀弹簧力
2)更换电磁阀组件:电磁阀弹簧力、衔铁升程
3)更换阀组件:衔铁升程、缓冲升程、针阀升程
4)更换油嘴:针阀升程
5)全新装配:衔铁升程、缓冲升程、针阀升程、电磁阀弹簧力、针阀弹簧力
3. 喷油器维修时,垫片调整只能作微调,不能无地调整来凑单点喷射油量;